Products - Tags and Labels - ColdSNAP Descending Temperature Recorders

Miniature ColdSNAP Records A Critical Falling Temperature From -20°C to +15°C with 2°C accuracy
The Telatemp ColdSNAP self-contained recorder monitors your shipments by recording an incursion below a critical low temperature threshold of refrigerated temperature sensitive products in storage or transit. The miniature self-adhesive ColdSNAP has a 2°C accuracy bimetallic sensing element that snaps at its rated cold temperature, permanently turning an indicating window from clear to bright red. Pull the plastic tab straight out to activate (do not break off).
The rugged all-mechanical plastic-housed recorder has a long storage life. This unique patented Telatemp design eliminates delicate chemical sensors, fragile glass and requires no batteries.
ColdSNAP decending temperature recorders can ship via ground without expending due to the activation tab. ColdSNAP+ models with ascending response temperatures of 130°F (54°C) or lower must ship via 2nd Day Air or faster and may seasonally incur an additional $6.00 charge for insulated packaging.
| ColsSNAP Specifications | |
|---|---|
| Accuracy | ±2° of rated value |
| Shipping | Special insulated packaging required to ship ascending recorders rated 130°F/54°C or lower |
| Shelf Life | 24 months when stored at room temperature 21°C (70°F) & 50% relative humidity |
| Materials | Polystyrene case with metal thermostatic sensing element |
| Adhesive | Double-sided self-adhesive backing on release liner |
| Packaging | Heat-sealed polyvinyl sleeves of 20 pieces, lot numbered with instruction card |
| Dimensions | 1.38 x 0.69 x 0.22 in. (35 x 18 x 6 mm) |
| Temperature Selection ColdSNAP |
|
|---|---|
| Critical Descending Temperature | Model No. |
| -20°C | CT-20C-D |
| -10°C | CT-10C-D |
| -5°C | CT-5C-D |
| 0°C | CT0C-D |
| +2°C | CT2C-D |
| +5°C | CT5C-D |
| +10°C | CT10C-D |
| +15°C | CT15C-D |
| Temperature Selection | ColdSNAP+ | ||||||
|---|---|---|---|---|---|---|---|
| Critical Descending Temperature |
Heat Sensor 38°C | Heat Sensor 41°C | Heat Sensor 43°C | Heat Sensor 46°C | Heat Sensor 49°C | Heat Sensor 54°C | Heat Sensor 60°C |
| -20°C |
CT-20C-D+38C | CT-20C-D+41C | CT-20C-D+43C | CT-20C-D+46C | CT-20C-D+49C | CT-20C-D+54C | CT-20C-D+60C |
| -10°C |
CT-10C-D+38C | CT-10C-D+41C | CT-10C-D+43C | CT-10C-D+46C | CT-10C-D+49C | CT-10C-D+54C | CT-10C-D+60C |
| -5°C |
CT-5C-D+38C | CT-5C-D+41C | CT-5C-D+43C | CT-5C-D+46C | CT-5C-D+49C | CT-5C-D+54C | CT-5C-D+60C |
| 0°C |
CT0C-D+38C | CT0C-D+41C | CT0C-D+43C | CT0C-D+46C | CT0C-D+49C | CT0C-D+54C | CT0C-D+60C |
| +2°C |
CT2C-D+38C | CT2C-D+41C | CT2C-D+43C | CT2C-D+46C | CT2C-D+49C | CT2C-D+54C | CT2C-D+60C |
| +5°C |
CT5C-D+38C | CT5C-D+41C | CT5C-D+43C | CT5C-D+46C | CT5C-D+49C | CT5C-D+54C | CT5C-D+60C |
| +10°C |
CT10C-D+38C | CT10C-D+41C | CT10C-D+43C | CT10C-D+46C | CT10C-D+49C | CT10C-D+54C | CT10C-D+60C |
| +15°C |
CT15C-D+38C | CT15C-D+41C | CT15C-D+43C | CT15C-D+46C | CT15C-D+49C | CT15C-D+54C | CT15C-D+60C |